Contactor
CYC2-388 / CYC2-396 Contactor (30A / 40A)
1/2 Pole Contactor (30A / 40A)
Straight-Through Wiring, Replaces 1 ~ Pole Devices Used Primarily in
Residential Central Air Conditioning
2. Features of Contactor :
Replaces many Type 117 contactors used by OEM' s
Universal style mounting bracket fits existing mounting holes.
Screw terminals and quick connection terminals for easy installation.
3. Specifications of Contactor:
| Temperature Range | -40°F to 150°F |
| Mechanical Life (no load) | Conforms to UL and ARI specifications |
| Electrical Life | Conforms to UL and ARI specifications 94-388 thru 94-390 achieve 200,000 cycles, make LRA at. 5 pf, break 125% of FLA at. 75 plat rated voltage, 10, 000 cycles make and break LRA at.5 pf rated voltage 94-394 thru 94-369 achieve 100,000 cycles, make LAR at.5 pf at rated voltage 6,000 cycles make and break LEA at .5 pf rated voltage |
| Weight (approximate) | 9.25 oz |
| Coils Frequency | 50/60 Hz |
| Coil Insulation | Class B (130°C) |
| Termination | Screw and Double Q.C. |
| Operate | 85% of nominal coil voltage; 110% maximum safe operate |
| Duty Cycle | Continuous |
| Steveco Number | Voltage | Ress DC | Current | Nominal | Max. Inrush |
| 30 Amp 40 Amp | AC | OHMS | MA | VA | VA |
| CYC2-388 CYC2-394 | 24 120 208/240 | 16.5 420 1825 | 208 42 21 | 5 5 5 | 20 20 20 |
| CYC2-389 CYC2-395 | |||||
| CYC2-390 CYC2-396 |
| Type | Voltage | FLA | LRA | RES |
| CYC2-388 thru CYC2-390 | 277 | 30 | 150 | 40 |
| 480 | 30 | 75 | 40 | |
| 600 | 30 | 50 | 40 | |
| CYC2-394 thru CYC2-396 | 277 | 40 | 200 | 50 |
| 480 | 40 | 100 | 50 | |
| 600 | 40 | 80 | 50 |