Panel Meters

DC Volmeters

Model: CYFC-F45V
Accuracy: Class 1.5
Specification: 20V 30V 50V 100V 150V 200V 250V 300V 450V 600V 1000V
Measuring ranges over 450V with external resistor (rated current 5Ma)
Heat resistance: case of non-combustible plastic material.


Frequency Meters

Model: CYFC-F45V
Accuracy: Class 1.0
Specification:
Voltmeter: 100V 220V 380V 440V
Frequency: 45-55Hz 45-65Hz 47-63Hz 57-63Hz 44-56Hz 54-66Hz 350-450Hz 450-550Hz 550-650Hz
Heat resistance: case of non-combustible plastic material.
Mounting type: DIN rail

AC Volmeters

AC Volmeters
Model: CYFC-F45V
Accuracy: Class 1.0
Specification: 30V 50V 75V 120V 120V 150V 250V 400V 450V 500V 600V
For450V-450KV, meters can use potential transformer with secondary voltage 100V.
Heat resistance: case of non-combustible plastic material
Mounting type: DIN rail

DC Volmeters

Model: CYFC-T45A
Accuracy: Class 1.5
Specification: 100μ A500μ A1mA 3mA 5mA 10mA 20mA 30mA 50mA 100mA 150mA 200mA 250mA
300mA 500mA 1A 3A 7.5A 10A 15A 20A
For 10A-10KA, use external 75 mV 60mV or 45mV shunt. For the direct reading from 20A to 60A meter the class is 2.5A.
Heat resistance: case of non-combustible plastic material.
Changeable scale: The dial plate with the same scale division, which is at the same internal value, can be changeable.

Power Factor Meter

Model: CYFC-PF45
Accuracy: Class 2.5
Single phase: 100V 220V 380V 440V current: 5A
Three phase: 100V 220V 380V 440V current: 5A
Specification: 0.5cap-1-0.5ind 0.3cap-1-0.7ind
0.4cap-1-0.4ind 0.7-1-0.2ind
Heat resistance: case of non-combustible plastic material.
Frequency: 50Hz or 60Hz
Mounting type: DIN rail

AC Volmeter

Model: CYFC-T45A
Accuracy: Class 1.5 2.5
Specification: 0.1A 0.5A 1A 7.5A 10A 15A 20A 30A 40A 60A
For 10-10KA, use external current transformer with secondary current 5A. For the direct reading from 20A to 60A meter, the class is 2.5.
Heat resistance: case of non-combustible plastic material.
Changeable scale: All scales with printing technique. The dial pate with the same scale division, which is at the same division and internal value, can be changeable.
pdfPanel Meter(Modular type)
Products List: ☆ Electrical Components
☆ Circuit Breaker
☆ Miniature Circuit Breaker
☆ Molded Case Circuit Breaker
☆ Earth Leak Circuit Breaker
☆ Residual Current Circuit Breaker
☆ Residual Current Device
☆ Current Transformer
☆ Safety Circuit Breaker
☆ Circuit Breaker Enclosure
☆ Hydraulic Magnetic Miniature Circuit Breaker
☆ Surge Protection Device
☆ Motor Protection Circuit Breaker
☆ AC Contactor
☆ Contact Block
☆ DC Operated AC Contactor
☆ Interlocking Contactor
☆ Contactor Starter
☆ Star-delta Reduced Voltage Starter
☆ Magnetic Starter
☆ Cam Starter
☆ Thermal Overload Relay
☆ Thermal Relay
☆ Power Relay
☆ Kilo-Watt Hour Meter
☆ Digital Panel Meter
☆ Meter Modular
☆ Power Meter
☆ Control Station
☆ Digital Frequency Meter
☆ Multimeter
☆ Ammeter & Voltmeter
☆ Meter Detector
☆ Current Transformer
☆ Distribution Box
☆ Distribution Boards
☆ Junction Box
☆ Bus Bar Support
☆ Industrial Plugs & Sockets
☆ Push Buttons & Indicators
☆ Magnetic Switch
☆ Isolating Switch
☆ Pedal Switch
☆ Push Button Switch
☆ Universal Changeover Switch
☆ Limit Switch
☆ Gear Switch
☆ Toggle Switches